Compartilhamento |
|
Use este identificador para citar ou linkar para este item:
http://tede2.unicap.br:8080/handle/tede/1021
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.creator | Gamboa, Hugo Geovanni Gomes | - |
dc.creator.Lattes | http://lattes.cnpq.br/9369234922606498 | por |
dc.contributor.advisor1 | Santos, Valdemir Alexandre dos | - |
dc.contributor.advisor1Lattes | http://lattes.cnpq.br/6361567059632670 | por |
dc.contributor.advisor-co1 | Sarubbo, Leonie Asfora | - |
dc.contributor.advisor-co1Lattes | http://lattes.cnpq.br/4691045388698504 | por |
dc.contributor.referee1 | Bernardino Júnior, Francisco Madeiro | - |
dc.contributor.referee1Lattes | http://lattes.cnpq.br/1934903225521860 | por |
dc.contributor.referee2 | Brandão, Yana Batista | - |
dc.contributor.referee2Lattes | http://lattes.cnpq.br/3860227097940599 | por |
dc.date.accessioned | 2018-07-19T13:31:13Z | - |
dc.date.issued | 2017-06-17 | - |
dc.identifier.citation | GAMBOA, Hugo Geovanni Gomes. Influência de diferentes anticongelantes para a água gelada produzida por um chiller de absorção de LiBr em uma usina termoelétrica na absorção de gases. 2016. Dissertação (Mestrado) - Universidade Católica de Pernambuco. Programa de Pós-Graduação em Desenvolvimento de Processos Ambientais. Mestrado em Desenvolvimento de Processos Ambientais, 2016. | por |
dc.identifier.uri | http://tede2.unicap.br:8080/handle/tede/1021 | - |
dc.description.resumo | Um menor consumo específico de combustível tem sido um dos principais motivos para realização de pesquisas e desenvolvimentos tecnológicos na área de produção térmica de energia. Uma das opções para se chegar a essa condição desejada é um controle eficiente da temperatura do bloco do motor do grupo gerador em uma termelétrica. Para isso, foram testados diferentes anticongelantes, os quais conferiram à água deionizada de preparação do refrigerante secundário, reduções em suas propriedades termofísicas de calor específico e condutividade térmica. Após a escolha do anticongelante com auxílio de experimentos, utilizando-se Delineamento Composto Central Rotacional (DCCR) e propondo um modelo de previsão, a solução de etilenoglicol a 30% teve seu desempenho em relação à água deionizada testado em uma unidade de bancada de um grupo gerador diesel. Os dados experimentais sobre a resposta da solução aquosa de etilenoglicol, frente a variações de temperatura na entrada do bloco do motor do grupo gerador foram acompanhados e armazenados em um registrador eletrônico (fieldlogger) e, posteriormente, analisado graficamente com auxílio de um computador. Apesar de um menor valor para o calor específico da solução aquosa de etilenoglicol ter, como esperado, produzido pulsos de respostas mais rápidas às variações de temperatura na entrada do bloco, a partir dos 70 oC a redução na condutividade térmica contribuiu para produção de pulsos menores para a água deionizada pura. Contudo, na faixa de potência testada a solução aquosa de etilenoglicol apresentou vantagens com redução de consumo específico da ordem de 42% entre 68 oC e 75 oC. | por |
dc.description.abstract | A lower specific fuel consumption has been the main reason for conducting research and technological developments in thermal production area of energy. One of the options to reach that desired condition is an efficient control of the engine block temperature in the generator group of a thermal plant. To this, they were tested different antifreeze, which gave the deionized water in preparation for the secondary refrigerant, reductions in thermos physical properties of their specific heat and thermal conductivity. After choosing the antifreeze with the help of experimental design using central composite rotate design (CCRD), the 30 % ethylene glycol solution had their performance compared to deionized water on a bench scale unit of a diesel generator group. Experimental data on the response of aqueous solution of ethylene glycol, against temperature variations at the entrance of the generator motor unit were monitored and stored in an electronic register (FieldLogger) and subsequently analyzed graphically with the aid of a computer. Although a lower value for the specific heat of the aqueous ethylene glycol solution had, as expected, produced pulses faster response to temperature changes in the engine block input, from the 70 ° C reduction in thermal conductivity contributed to production of pulses lower for pure deionized water. However, in the power range tested the aqueous solution of ethylene glycol presented as advantages a reduction of specific fuel consumption of the order of 42% between 68 °C and 75 °C. | eng |
dc.description.provenance | Submitted by Biblioteca Central (biblioteca@unicap.br) on 2018-07-19T13:31:13Z No. of bitstreams: 2 hugo_geovanni_gomes_gamboa.pdf: 5687774 bytes, checksum: dc28db58ddab00d3a71f4246989eb1c4 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) | eng |
dc.description.provenance | Made available in DSpace on 2018-07-19T13:31:13Z (GMT). No. of bitstreams: 2 hugo_geovanni_gomes_gamboa.pdf: 5687774 bytes, checksum: dc28db58ddab00d3a71f4246989eb1c4 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-06-17 | eng |
dc.format | application/pdf | * |
dc.language | por | por |
dc.publisher | Universidade Católica de Pernambuco | por |
dc.publisher.department | Departamento de Pós-Graduação# | por |
dc.publisher.department | #-8854052368273140835# | por |
dc.publisher.department | #500 | por |
dc.publisher.country | Brasil | por |
dc.publisher.initials | UNICAP | por |
dc.publisher.program | Mestrado em Desenvolvimento de Processos Ambientais# | por |
dc.publisher.program | #7773858030179640429# | por |
dc.publisher.program | #500 | por |
dc.rights | Acesso Aberto | por |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | - |
dc.subject | Dissertations | eng |
dc.subject | Experimental planning | eng |
dc.subject | Antifreeze solutions | eng |
dc.subject | Rotational central composite design | eng |
dc.subject | Dissertações | por |
dc.subject | Planejamento experimental | por |
dc.subject | Soluções anticongelantes | por |
dc.subject | Delineamento composto central rotacional | por |
dc.subject.cnpq | CIENCIAS BIOLOGICAS::BIOLOGIA GERAL# | por |
dc.subject.cnpq | #-1634559385931244697# | por |
dc.subject.cnpq | #600 | por |
dc.title | Influência de diferentes anticongelantes para a água gelada produzida por um chiller de absorção de LiBr em uma usina termoelétrica na absorção de gases. | por |
dc.type | Dissertação | por |
Aparece nas coleções: | Desenvolvimento de Processos Ambientais |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
hugo_geovanni_gomes_gamboa.pdf | Dissertação na íntegra | 5,55 MB | Adobe PDF | Baixar/Abrir Pré-Visualizar |
Este item está licenciada sob uma Licença Creative Commons