Compartilhamento |
|
Use este identificador para citar ou linkar para este item:
http://tede2.unicap.br:8080/handle/tede/1078
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.creator | Barros, Tácylla Ceci Melo Freitas de | - |
dc.creator.Lattes | http://lattes.cnpq.br/7089767911460342 | por |
dc.contributor.advisor1 | Monteiro, Eliana Cristina Barreto | - |
dc.contributor.advisor1Lattes | http://lattes.cnpq.br/3808888967301263 | por |
dc.contributor.referee1 | Mota, João Manoel de Freitas | - |
dc.contributor.referee1Lattes | http://lattes.cnpq.br/7401710771055096 | por |
dc.contributor.referee2 | Oliveira, Romilde Almeida de | - |
dc.contributor.referee2Lattes | http://lattes.cnpq.br/9272579827887449 | por |
dc.date.accessioned | 2019-03-29T18:55:30Z | - |
dc.date.issued | 2018-11-23 | - |
dc.identifier.citation | BARROS, Tácylla Ceci Melo Freitas de. Estudo experimental da influência da interface espaçador/concreto na corrosão de armaduras desencandeada por íons cloreto. 2018. 130 f. Dissertação (Mestrado) - Universidade Católica de Pernambuco. Pró-reitoria Acadêmica. Coordenação geral de Pós-Graduação. Mestrado em Engenharia Civil, 2018. | por |
dc.identifier.uri | http://tede2.unicap.br:8080/handle/tede/1078 | - |
dc.description.resumo | Atualmente, muitos casos de deterioração prematura, nas estruturas de concreto armado, vêm sendo registrados. Um dos que mais se destaca é a corrosão de armaduras, podendo ocorrer através de íons cloreto ou por uma frente de carbonatação. A fim de se garantir o cobrimento solicitado em projeto nas estruturas de concreto armado, são utilizados espaçadores. Com o cobrimento adequado, a durabilidade da peça tende a ser maior. Em contrapartida, a interface espaçador/concreto pode se tornar um ponto frágil para a entrada de agentes agressivos, como os íons cloreto, por exemplo. O objetivo do trabalho foi realizar um estudo experimental, para analisar a influência da interface espaçador/concreto na corrosão de armaduras desencadeada por íons cloreto, quando utilizados diferentes tipos de espaçadores. A partir disso, três famílias de corpos de prova prismáticos de concreto armado foram moldadas, são elas: sem espaçador (referência), com espaçador de argamassa produzido em obra e com espaçador industrializado de argamassa. Esses corpos de prova, foram submetidos ao ensaio de indução da penetração de íons cloreto por meio de ciclos de secagem e imersão parcial. Ao longo do ensaio, o potencial de corrosão foi aferido. Realizouse também, ensaios complementares de velocidade de onda ultrassônica, de presença de cloretos pelo método colorimétrico com nitrato de prata e perda gravimétrica da massa das armaduras. Também foram realizados ensaios nos próprios espaçadores. Após a análise de todos os resultados, concluiu-se, que os corpos de prova com espaçadores industrializados de argamassa foram os que mais favoreceram o início da corrosão, evidenciando a influência direta da presença dos espaçadores na corrosão de armaduras do concreto. | por |
dc.description.abstract | Currently, many cases of premature deterioration in reinforced concrete structures have been recorded. One of the most outstanding is the corrosion of reinforcements, which may occur through chloride ions or by a carbonation front. In order to guarantee the required design coverage in reinforced concrete structures, spacers are used. With adequate cover, the durability of the piece tends to be higher. In contrast, the spacer/concrete interface can become a fragile point for the entry of aggressive agents, such as chloride ions, for example. The objective of this work was to conduct an experimental study to analyze the influence of the spacer/concrete interface on the corrosion of reinforcements triggered by chloride ions, when using different types of spacers. From this, three families of prismatic reinforced concrete specimens were molded, they are: without spacer (reference), with mortar spacer produced on site and with industrialized mortar spacer. These test specimens were submitted to the chloride ion penetration induction test by means of cycles of drying and partial immersion. Throughout the test, the corrosion potential was measured. Also, complementary tests of ultrasonic wave velocity, presence of chlorides by the colorimetric method with silver nitrate and gravimetric loss of the mass of the reinforcements were carried out. Tests were also carried out on the spacers themselves. After the analysis of all the results, it was concluded that the specimens with industrialized mortar spacers were the ones that favored the beginning of the corrosion, evidencing the direct influence of the presence of the spacers in the corrosion of concrete reinforcement. | eng |
dc.description.provenance | Submitted by Biblioteca Central (biblioteca@unicap.br) on 2019-03-29T18:55:30Z No. of bitstreams: 2 tacylla_leci_melo_freitas_barros.pdf: 5075809 bytes, checksum: f91be50ef0ce9de2888d47af42ce1ddd (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) | eng |
dc.description.provenance | Made available in DSpace on 2019-03-29T18:55:30Z (GMT). No. of bitstreams: 2 tacylla_leci_melo_freitas_barros.pdf: 5075809 bytes, checksum: f91be50ef0ce9de2888d47af42ce1ddd (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-11-23 | eng |
dc.format | application/pdf | * |
dc.language | por | por |
dc.publisher | Universidade Católica de Pernambuco | por |
dc.publisher.department | Departamento de Pós-Graduação | por |
dc.publisher.country | Brasil | por |
dc.publisher.initials | UNICAP | por |
dc.publisher.program | Mestrado em Engenharia Civil | por |
dc.rights | Acesso Aberto | por |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | - |
dc.subject | Dissertações | por |
dc.subject | Concreto armado | por |
dc.subject | Corrosão e anticorrosivos | por |
dc.subject | Cloretos | por |
dc.subject | Dissertations | eng |
dc.subject | Reinforced concrete | eng |
dc.subject | Corrosion and anticorrosion products | eng |
dc.subject | Chlorides | eng |
dc.subject.cnpq | ENGENHARIAS::ENGENHARIA CIVIL | por |
dc.title | Estudo experimental da influência da interface espaçador/concreto na corrosão de armaduras desencadeada por íons cloreto. | por |
dc.type | Dissertação | por |
Aparece nas coleções: | Engenharia Civil |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
tacylla_leci_melo_freitas_barros.pdf | Dissertação na íntegra | 4,96 MB | Adobe PDF | Baixar/Abrir Pré-Visualizar |
Este item está licenciada sob uma Licença Creative Commons