Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://tede2.unicap.br:8080/handle/tede/74
Registro completo de metadados
Campo DCValorIdioma
dc.creatorSilva, Marcelo Lima-
dc.creator.Latteshttp://lattes.cnpq.br/2997132867952985por
dc.contributor.advisor1Oliveira, Romilde Almeida de-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/9272579827887449por
dc.contributor.referee1Silva, Fernando Artur Nogueira-
dc.contributor.referee1Latteshttp://lattes.cnpq.br/7084105376262463por
dc.contributor.referee2Silva, José Jéferson do Rêgo-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/3569829423106163por
dc.date.accessioned2017-06-01T17:57:37Z-
dc.date.available2016-09-27-
dc.date.issued2016-04-08-
dc.identifier.citationSILVA, Marcelo Lima. Colapso em caso de incêndio em edifícios de alvenaria resistente. 2016. 73 f. Dissertação (Mestrado em Engenharia Civil) - Universidade Católica de Pernambuco, Recife, 2016.por
dc.identifier.urihttp://tede2.unicap.br:8080/handle/tede/74-
dc.description.resumoO risco de colapso em estruturas de prédio do tipo caixão é alarmante. A maioria desses prédios tem algum risco potencial. Cerca de 10% da população de Pernambuco habitam nesse tipo de edificação. O Corpo de Bombeiros Militar de Pernambuco (CBMPE) atendeu no ano de 2012 na RMR a 314 ocorrências em residências e em 2013 teve 325 incêndios residenciais. Na cidade de Recife, em 2013, foram 198 ocorrências de incêndio residenciais sendo 36 em edificações multifamiliares, mesmo tipo de ocupação dos prédios tipo caixão. Neste trabalho, apresenta-se um estudo de caso de um incêndio em um apartamento, onde foram observados seus efeitos sobre a alvenaria e verificou-se se esses efeitos poderiam provocar o colapso em um edifício de Alvenaria Resistente, uma vez que nesse tipo de edificação as paredes têm função estrutural. Essas estimativas foram acerca da resistência à compressão nas paredes considerando as reduções de resistência decorrentes dos danos provocados pelo incêndio. Estudos demonstram que os prédios em alvenaria resistente para terem a sua estabilidade assegurada dependem da participação do revestimento na resistência à compressão. As normas relativas à alvenaria estrutural recomendam que não deva ser considerada a contribuição do revestimento. No entanto, sem a contribuição do revestimento, a estrutura estaria numericamente fora dos limites de segurança. Efeitos decorrentes do incêndio poderão ocasionar destruição do revestimento e um terço do bloco cerâmico nas faces expostas ao incêndio, o que deve representar a ruína do edifício se ocorrido no pavimento térreo.por
dc.description.abstractThe risk collapse of Building type box is alarming. Most of these buildings have some potential risk. About 10% of the population of Pernambuco lives in this type building. The Military Fire Department of Pernambuco (CBMPE) attended in 2012 in RMR 314 occurrences in residential building and in 2013 had 325 residential fires. In the city of Recife in 2013 were 198 occurrences of residential fire being 36 in multifamily buildings, the same occupation of the buildings type box. In this work is presented a case study of a fire in an apartment, where its effects on masonry were observed, and it is verified that these effects could lead to collapse in a Resistant Masonry building, because in this type of building the walls is supporting masonry structure. Such estimates were about the strength in compression of the walls considering reductions in resistance resulting from fire damage. Studies show that the resistant masonry buildings to have their guaranteed stability depend on the participation of the coating on compressive strength. The rules for the structural masonry recommend that should not be considered the contribution of the coating in its strength in compression. However, without the contribution of the coating the structure was numerically outside safe limits. The effects of fire may result in the destruction of the plaster on one side of the wall, and around one third of the ceramic block, which should represent the ruin of the building if it had occurred on the ground floor.eng
dc.description.provenanceMade available in DSpace on 2017-06-01T17:57:37Z (GMT). No. of bitstreams: 1 marcelo_lima_silva_textual.pdf: 1991447 bytes, checksum: b4453b4c4677952d7d84a16e3945a5ed (MD5) Previous issue date: 2016-04-08eng
dc.formatapplication/pdfpor
dc.languageporpor
dc.publisherUniversidade Católica de Pernambucopor
dc.publisher.departmentEngenharia Civilpor
dc.publisher.countryBRpor
dc.publisher.initialsUNICAPpor
dc.publisher.programMestrado em Engenharia Civilpor
dc.rightsAcesso Abertopor
dc.subjectresistência de materiaispor
dc.subjectconstrução civilpor
dc.subjectalvenariapor
dc.subjectdissertaçõespor
dc.subjectresistance materialeng
dc.subjectconstructioneng
dc.subjectmasonryeng
dc.subjectdissertationseng
dc.subject.cnpqCNPQ::ENGENHARIAS::ENGENHARIA CIVILpor
dc.titleColapso em caso de incêndio em edifícios de alvenaria resistentepor
dc.typeDissertaçãopor
Aparece nas coleções:Engenharia Civil

Arquivos associados a este item:
Arquivo TamanhoFormato 
marcelo_lima_silva_textual.pdf1,94 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.